Product Categories: Maintenance Kit Instructions,
Maintenance Kit Instructions,
HP LaserJet IIP / IIIP (LX) Maintenance Kit Instructions
HP LX(IIP\IIIP)
MAINTENANCE KIT INSTRUCTIONS
The following parts
are included in this maintenance kit:
1 Canon LX Fuser
RG1-1788
1 Paper Feed Roller
Assembly RG1-1778
1 Separation Pad
RG1-1912
1 Transfer Roller
RA1-7627
1 Pick Up Roller
Assembly RG1-1792
1 Face-Down Delivery
Assembly RG1-1791
Please Note: Turn
the printer off, unplug it, and allow it to sit for 30 minutes before
performing these
maintenance procedures.
Separation Pad &
Paper Feed Roller Removal & Replacement:
1. Open the MP tray
and lift the tab to release and open the paper path door. Remove the
toner cartridge.
2. Remove the
separation pad by pulling forward on its clear Mylar tab.
3. Push down on the
tab behind the center gear off the paper feed roller so that the shaft lifts
up. Gently pull the
right side rubber roller forward from its clip then pull the left side roller
from its clip.
4. Push down on the
tab behind the center gear. Snap the left side shaft of the new paper feed
roller into place,
then the right side. The right side will not be held in place as lightly as the
left side, this is
normal.
5. Drop the new
separation pad into place (with clear Mylar tab on top). Press in on the center
until it snaps into
place.
****IMPORTANT****
Ensure that the
lever to the left of the right side rubber roller is mounted UNDERNEATH the
shaft.
Fuser Removal:
1. Lift the spring
loaded internal access door.
2. Locate and remove
the five collateral screws securing the fuser.
3. Lift the left
side of the fuser while gently but firmly bending the left side of the paper
path
door outward. After
the shaft is clear of the holding tab, lift the right side of the fuser in the
same manner. Pull
the fuser from the inside of the paper path door.
Transfer Roller
Assembly Removal:
1. Lift up on the
blue gear on the left side of the transfer roller assembly until it snaps free
of
its clip.
2. Pull the transfer
roller assembly forward and to the left and remove it from the inside of the
paper path door.
Pick Up Roller
Assembly Removal/Replacement:
1. Locate and remove
the three black screws securing the pick up roller assembly (one on the
far left side of the
shaft, two on the far right side of the shaft).
2. Lift the pick up
roller assembly and remove it from the inside of the paper path door.
3. Place the new
pick up roller assembly into position (with the solenoid and gear towards the
right), line up the
left and right mounting brackets and re-secure the three screws (one on
the left, two on the
right).
Transfer Roller
Assembly Replacement:
1. Pull the blue
gear from the transfer roller shaft.
2. Grasp the
mounting bracket and gently, but firmly pull the transfer roller from the frame.
Keep your hand over
the top of the shaft to contain the shaft clip in case it pops off. Remove
the transfer roller
from the frame.
3. Snap the new
transfer roller into place. The long end goes towards the resistor and
mounting bracket.
Use tweezers or a small flathead screwdriver to replace the shaft clip, if
necessary.
4. Replace the blue
gear onto the shaft with its flat edge facing outwards.
5. Slide the right
side shaft end of the transfer roller assembly into the clip.
6. Mount the left
side transfer roller bracket on the pick up roller assembly shaft.
7. Press down on the
blue gear until it snaps into place.
Internal Access Door
Assembly Removal/Replacement:
1. Lift the spring
loaded internal access door. Locate and remove the three self tapping
mounting screws (one
black screw on the far left, two silver screws on the far right).
2. Lift the internal
access from the inside of the paper path door.
3. Inspect the four
oval rollers on the paper path door. Clean them of any debris, dust or
paper and wipe them
down with alcohol and a lint free towel.
4. Open the spring
loaded arms of the new internal access door and position it on the inside of
the paper path door
(the shorter arm with the three gears goes toward the right).
Fuser Replacement:
1. Line up the five
screw holes on the new fuser and the inside of the paper path door.
2. Pull the left
side of the paper path door outward gently, yet firmly and push down on the left
side of the fuser
until it snaps into place. Install the right side of the fuser in the same
manner.
3. Re-secure the
five collared screws.
4. Close the spring
loaded internal access door.
|
Type: Click above link for instructions
|
|
| |
|